BFI-E3-22-0105-1F42-01
Article number 61632
- Output power 1.1 kW
- Output 1x230 VAC, 10.5 A
- Input voltage 1x200-240 VAC
- IP20
Fakta
General description
Article number | 61632 |
Warranty | 2 year |
Mechanical
IP class | IP20 |
Physical size | Size 2 |
Measurements (H x W x D) | 221 mm x 110 mm x 150 mm |
Weight | 1.7 kg |
Typical power loss at rated power | 0,02 |
Main switch | No |
Built in Main switch, control switch and potentiometer | No |
Conformal coated PCBs | Yes, 3C2/3S2 conformal coated PCBs |
Output ratings
Output voltage | 1 x 230 VAC |
Rated motor current | 10.5 A |
Overload capacity | 150% for 60 seconds, 175% for 2,5 seconds |
Motor power | 1.5 kW |
Output frequency | 0 – 500Hz, 0.1Hz resolution |
Built-in brake transistor | Yes |
Regenerative capacity | 100 % ED |
Input ratings
Supply voltage | 200 – 240VAC ± 10% |
Voltage fluctuations | +/- 10% |
Phase imbalance | 3% maximum allowed |
Displacement factor | > 0.98 |
Supply frequency | 48 – 62Hz |
Power cycles | 120 per hour maximum, evenly spaced |
Control specification
Control modes | V/F Voltage Vector, Energy Optimised V/F, Sensorless Vector Speed Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Open Loop PM Vector Control |
Current/torque limitation | Current limitation |
PWM frquency | 4-32 kHz effective |
Stopping mode | Ramp to Stop: User Adjustable 0.1 – 600 seconds,Coast to Stop |
Braking | Motor Flux Braking |
Skip frequency | No |
Analog setpoint control | 0 to 10V, 10 to 0V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA |
Digital setpoint control | 4 fixed speeds, Motorised Potentiometer, Keypad, Modbus RTU, CANopen |
Communication
Modbus RTU | 9.6 - 115.2 kbps selectable (8N1, 8N2, 8E1, 8O1) |
BACnet MS/TP | No |
Modbus TCP | No |
Ethernet IP | No |
EtherCat | No |
Profinet IO | No |
Profibus DP(DPV1) | No |
Device Net | No |
CC-Link | No |
CAN open | Yes, 125 - 1000 kbps |
Display
Programmable display | No |
Multi language OLED display | No |
External OLED display | Yes |
LED display | Yes |
HVAC
PID-control | PI-control with sleep/wake up |
Spin start | Yes |
Pump dry protection | No |
Pump prime and burst protection | No |
Stir function | No |
Motor pre-heat | No |
Broken impeller and broken belt detection | No |
Automatic cleaning for pumps | No |
Bypass control | No |
Fire mode | Yes |
Control terminals
Power supply | 100 mA @ 24 VDC, 10 mA @ 10 VDC |
Inputs | 4 in total, 2 Digital, 2 Analog or Digital, selectable |
Digital inputs | 8-30 V DC, PNP, Response time: < 4 msec, Internal or external supply |
Analog inputs | Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling |
Outputs | 2 total, 1 relay, 1 analog or digital |
Digital transistor outputs | 24VDC/20 mA, Internal supply |
Relay outputs | Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC |
Analog outputs | 0 to 10 V, 10 to 0 V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA |
Safety inputs | No |
Extra IOs | No |
Control features
Speed control Master/slave | Slave |
Modbus master functionality | No |
Advanced hoist control | No |
Built-in PLC | No |
Standard compliances
Low voltage directive | 2014/35/EU |
EMC directive | 2014/30/EU Cat C1 according to EN61800-3:2004 |
Conformance | CE, UL |
Machine directive | 2006/42/EC |
Marine approvals | No |
Safe torque OFF | No |
Restriction of hazardous substances | RoHS2 |
Registration evaluation and authorisation of chemicals | Reach |
Earth leakage current | EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing |
DC Bus discharge time | EN 61800-5-1:2007 |
Electrostatic discharge | EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009. |
Dielectric strength | 61800-5-1: 2007 |
Surge | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006. |
Electrical fast transient burst | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004. |
Ambient conditions
Temperature operation | -20 to 50 °C |
Humidity | 95% max, non-condensing |
Maintenance
Fault memory | Last 4 Trips stored with time stamp |
Data logging | Logging of data prior to trip, Current, Temperature, DC Bus Voltage |
Maintenence indicator | No |
Monitoring | Hours Run Meter, kWh/MWh meter |
Resurser
Knowledge
- Alarm code running single phase motor with 3-phase output BFI
- 24 VAC connected to terminal 1 will damaged the drive
- Overvoltage levels
- Thermal protection inside motor connected to BFI-E3/P2/H3
- OLED Remote External Keypad, Working with Multiple Drive Networks
- Single phase motors run by BFI-E3/H3/P2
- DC-choke for BFI-E3, BFI-H3 and BFI-P2
- Analog input BFI-E3
- BFI to factory default
- Alarm, Excessive DC-rippel
- Alarm O-I Instantaneous over current on drive output
- Alarm, INHIBIT
- Fans, external cooling fans
- Profibus contacts for BFI-P2 and BFI-H3
- DC-ripple
- Modbus RTU and Modbus TCP communication at the same time
- PID-control. Scaling of actual processvalue in display and unit
- Forced manual control when runing Fieldbus control
- Emergency runing by a digital signal when normal running by Fieldbus/Ethernet
- CC-Link communication
- BFI-H3, PID reference/setpoint from Fieldbus
- Alarm, Excessive DC rippel
- Cooling fans in the BFI-P2
- Alternate between EtherNet control and Digital/analog
- Main switch in BFI-P2
- Overcurrent trip
- Power consumption in standby
- Encoder feedback
- BFI as DC / AC Converter
- BFI cable connectors fork type
Drawings
- Cable CAB155: Cable for CANopen between any product and BFI
- Cable CAB154: Cable for CANopen between X2 Control and BFI
- Cable CAB114: Cable for ModBus RS485 between any product and BFI
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- CAD drawings All BFI-E3 (STEP)
- CAD drawings All BFI-E3 dxf-files
- CAD Drawings: BFI-H3 All models (dwg/pdf)
- CAD drawings BFI-H3 All models (step)
- CAD drawings BFI-H3 IP20 All sizes (step)
- Mechanical drawings: BFI-P2, STEP-files
- Mechanical drawings BFI-P2, (*.pdf and *.dxf)
- CAD Drawing BFI-C2 Size2 (step files)
- CAD Drawing BFI-C2 Size1A (step files)
Program examples/Start-up
- Program example iX Developer: X2 Base control of BFI by Modbus RTU
- Program example CODESYS and iX: X2 Control communication with BFI by Modbus RTU
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus RTU
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by CANopen
- Program example CODESYS and iX: X2 Control communication with BFI by CANopen
- Programexample Modbus TCP communication with BFI-E3 from X2 control
- Program example BCS Tools and iX: Nexto communication with BFI by EtherCAT
- Program example iX Developer: X2 Base control of BFI by Modbus TCP
- Program example CODESYS and iX: X2 Control communication with BFI_P2/BFI-H3 by Modbus TCP
- Program example CODESYS and iX: X2 Control communication with BFI by EtherCat
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus TCP
- Program example BCS Tools and iX: Nexto communication with BFI by ModbusTCP
- Program example BFI Tools: Internal PLC-program exampel for Positioning
Applications
- Application note BFI-E3, Using The Display Scaling Function
- Application note BFI-E3, Using Standby Mode
- Application note BFI-E3, Setting the Required Stopping Mode
- Application note BFI-E3, Selecting the Start - Restart Mode
- Application note BFI-E3, Programming the Drive User Relays
- Application Note BFI-E3, PI Closed Loop feedback
- Application note BFI-E3, Additional relay output option modules
- Application Note BFI-H3, Fire Mode Operation
- Application Note BFI-H3, Bypass Operation
- Application note BFI-H3. Pump clean function
- Application note BFI-H3. Multi Pump Cascade control, DOL
- Application Note BFI-H3, Locking Parameters to Prevent Changes
- Application Note BFI-H3, Optiflow Multi Pump Cascade Control
- Application Note BFI-H3, Setting the Motor Nameplate Details
- Application Note BFI-H3, PID-control
- Application Note BFI-H3, Setting up Acceleration and Deceleration Ramp Rates
- Application Note BFI-H3, Setting the Required Stopping Mode
- Application note BFI-P2, Using The Display Scaling Function
- Application note BFI-P2, Use of Drive on generator supplies
- Application note BFI-P2, Selecting the Start - Restart Mode
- Application note BFI-P2, Scaling of displayed value
- Application note BFI-P2, Remote Push-button Speed Control
- Application note BFI-P2, Programming the Drive User Relays
- Application note BFI-P2, Permanent Magnet and Brushless DC Motor Control
- Application note BFI-P2, Mounting Drives in control panels
- Application Note: BFI-P2, Modifying the Constant V-F Output characteristic
- Application note BFI-P2, Master Slave Network Operation
- Application note BFI-P2, Hoist Applications
- Application note BFI-P2, High Frequency Firmware
- Application note BFI-P2, Fan components in Drive construction
- Application note BFI-P2, Encoder-less Vector Control for 3 Phase Induction Motors
- Application note BFI-P2, Displaying Motor Speed in rpm
- Application note BFI-P2, Setting Required Stopping Mode
- Application note BFI-P2, Locking Parameters to Prevent Changes
- Application note BFI-P2, Setting Motor nameplate Details
- Application note BFI-P2, Skip Frequency function
- Application note BFI-P2, Using Multiple Motor in Parallel
Brochures
Manuals
- Start-up manual BFI-E3 English
- Manual Modbus RTU 485-communication BFI-E3 (English)
- Manual: User Guide BFI-E3 (English) ver1.20
- Manual CANopen BFI-E3
- Manual BFI-Tools, PC-software for BFI
- Manual BFI-Smartstick for programming by Bluetooth
- Kom-Igång dokument BFI-E3 Swedish
- Manual for Programexample Modbus TCP communication with BFI-E3 from X2 control
- Manual Modbus RTU RS-485- communication
- Manual Profibus DP BFI-P2 and BFI-H3
- Kom-Igång Frequency Inverter (Swedish) BFI-H3 (KI00362C)
- Manual (english) BFI-H3 , User Manual version 3.08
- Start-Up-Document (english) Frequency Inverter BFI-H3 (KI00363C)
- Manual Modbus RTU 485-communication
- Manual Performance Inverter BFI-P2 (english) , version 3.04
- Kom-Igång dokument BFI-P2 Swedish
- Manual CanOpen BFI-P2
- Start-Up-Document BFI-P2, Performance Inverter (English KI00306B )
- Manual BFI-C2, Engineering Guide Issue 08
Certificates
- Manufacture Declaration for US and Canada
- Manufacture Declaration BFI-E3: CE Declaration of Confirmity
- Manufacturer declaration: BFI-H3 Declaration of Conformity CE
- Manufacturer declaration: BFI-P2 DNV Marine Approval
- Manufacturer declaration: BFI-P2 CE Declaration of Conformity
Data sheets
- Datasheet: Input AC Line chokes to BFI
- Datasheet: Sine wave filter
- Datasheet: Output chokes for BFI
- Specification of all BFI, Functions/Hardware
- Datasheet: External EMC-filters for BFI
- Datasheet Additional relay for BFI-E3, ODP-2ROUT-BFI
- Datasheet: Cables for Modbus RTU to BFI
- Datasheet: External parameterunit OPT-2-OPPAD-BFI
- Datablad: Extra reläutgång till BFI-E3, ODP-2ROUT-BFI
- Datablad Externt bromsmotstånd till BFI-E3 och BFI-P2.
- Datablad Extern parameterenhet OPT-2-OPPAD-BFI
- Datablad Kablage för Modbus RTU mot BFI
- Datasheet Isolator switch option for BFI-P2 IP55
- Datasheet Additional option board with 3 additional realy outputs
- Datasheet Additional option board with 3 digital inputs and one relay output
- Datasheet: TTL encoder feedback for BFI-P2
- Datasheet: Extra IO by CanOpen to BFI-P2, OPT-2-CANIO-BFI
- Datablad Pulsgivaråterkoppling till BFI-P2
Configuration files
- Configuration files CanOpen (eds) for BFI-P2 and BFI-E3.
- Configuration file Profibus DP (gsd) for BFI-H3 and BFI-P2.
- Configuration file EtherCat (xml) for BFI-H3 and BFI-P2.
- Configuration file DeviceNet (eds) for BFI-H3 and BFI-P2
- Configuration file Profinet (xml) for BFI-H3 and BFI-P2
Software
Limited availability
BFI-E3-22-0105-1F42-01
Article number 61632
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-