BCS-NJ1005
Digital input/output mixed module
- 8 digital inputs, 8 digital outputs 24 VDC
- Sink/Source input option with 2 isolated groups, source outputs with 1 isolated group
- Built-in high-speed counters, 20Khz and 2 Khz
- Display for module diagnostics and input state indication
- Removable terminal blocks with support for field wiring fixation
Important life cycle dates, read more ->
Facts
General description
Article number | 66.014.331-2 |
Warranty | 2 year |
Mechanical
Certificates | CE, ROHS |
Module dimensions (W x H x D) | 18.00 x 114.63 x 117.46 mm |
Net weight | 200 g |
Power
Current consumption from backplane rack | 160 mA |
System
Status and diagnostics indication | Yes |
External power supply | 19.2 - 30 VDC |
Update time | 2 ms |
Resources
Program examples/Start-up
- BCS Tools Nexto - Digital IO modules NX1001 NX1005 NX2001 NX2020 (KI00348B)
- Program example BCS Tools and iX: Nexto communication with BFI by EtherCAT
- Kom i gang med Nexto XPress - Høyhastighets datalogging (Norwegian)
- BCS Tools/Nexto - Modbus TCP and Crevis I/O, init ST-3702
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus RTU.
- Kom i gang med Nexto XPress - SQL kommunikasjon (Norwegian)
- Kom i gang med Nexto XPress - MQTT kommunikasjon (Norwegian)
- Kom i gang med Nexto XPress - HTML5 websider (Norwegian)
- Kom i gang med Nexto XPress - Grunnleggende (Norwegian)
- Get Started with Nexto Xpress - MQTT communication
- Get Started with Nexto Xpress - The Basics
- Get Started with Nexto Xpress - High speed datalogging
- BCS Tools, MODBUS Symbol Server/Client
- Get started with Nexto Xpress - IEC60870-5-104
- Get Started with Nexto Xpress - Database communication
Catalogues
Software
Drawings
Firmware
Data sheets
Manuals
- BCS Nexto modular/Nexto Xpress - PID advanced library
- BCS Tools - User Manual
- BCS Tools - Programming Manual
- BCS Tools - Datasheet
- BCS NX940x - User's manual (Connectors of Nexto Series)
- BCS NX92xx - User's manual (RJ45-RJ45 Cables)
- BCS Nexto Series - User Manual
Knowledge
- BCS-Nexto/Nexto Xpress - Number of supported ARTI connections
- Clarification about the force function in CODESYS
- BCS Tools - The address %QBxxxxx not defined in any device
- BCS Tools - OPC connection to the CPU or the simulator in BCS Tools.
- BCS Nexto - ARTI/OPC communication
- Example of a Modbus/TCP client via PLC code using the Oscat library
- BCS Nexto Xpress/Modular - MQTT version
- LTB Life Cycle Notification BCS-NX940x spareparts
- Nexto I/O update with EtherCat master
- Nexto - Persistent variables loose their value if the name of the application changes
- Nexto - Check operating status of I/O modules
- BCS Tools - Edit CSV files with Excel 2013 or newer might destroy and make the csv files unusable for BCS Tools
Certificates
- BCS Nexto modular - DNV approval
- BCS Nexto/Nexto Xpress - UL/cUL certificate
- BCS Nexto Modular - CE EMC/LVD Declaration
Information document
Configuration files
Limited availability
BCS-NJ1005
Digital input/output mixed module
EOL - End Of Life:
2022-09-30
LTB - Last Time Buy:
2022-11-30
LTD - Last Time Delivery:
2022-12-31
LTR - Last Time Repair:
2025-12-31
Replacement Parts:
No replacement part available