BCS-NX6000
Analog input module
- 8 analog inputs
- Software configurable ranges
- Current and Voltage measurement
- Display for module diagnostics and input state indication
- Removable terminal blocks with support for field wiring fixation
- Hot-Swap
- One touch diagnostics for easy maintenance
Facts
General description
Article number | 66.014.322-3 |
Warranty | 2 year |
Mechanical
Certificates | CE, ROHS, UL, DNV |
Module dimensions (W x H x D) | 18.00 x 114.63 x 117.46 mm |
Net weight | 200 g |
Power
Current consumption from backplane rack | 270 mA |
System
Hot Swap | Yes |
One Touch Diag (OTD) | Yes |
Status and diagnostics indication | Yes |
Converter resolution | 24 bits monotonicity guaranteed, no missing codes |
Data format | 16 bits in two’s complement, justified to the left |
Precision | ± 0.1 % of full scale rating @ 25 °C |
Ranges | 0 to 10 VDC, -10 to +10 VDC, 0 to 20 mA, 4 to 20 mA, -20 mA to +20 mA |
Digital IO
Update time | 1 ms with one channel, 6 ms with all channels |
Resources
Program examples/Start-up
- BCS Tools Nexto - Firstscan bit
- BCS Tools Nexto -Programming path setup (KI00345B)
- BCS Tools Nexto - Program example datalogging function
- BCS Tools Nexto - Connecting Nexto and iX with Modbus TCP (KI00360)
- BCS Tools Nexto - Compile and Project transfer (KI00346)
- BCS Tools Nexto - Program example read write real time clock
- BCS Tools Nexto - Program example read write IP address information with functionblock
- BCS Tools Nexto - Program example read task and application information
- BCS Tools Nexto - Program example PID functionblock
- BCS Tools Nexto - Digital IO modules NX1001 NX1005 NX2001 NX2020 (KI00348B)
- BCS Tools Nexto – Analog IO NX6000 and NX6100 (KI00347B)
- Nexto - Library supporting NI1000LG sensor type
- BCS Tools Nexto - Modbus RTU \ tcp and Crevis I/O
- BCS Tools Nexto - Eventbased Modbus TCP communication
- BCS Tools Nexto - Modbus TCP and Crevis I/O (KI00350)
- BCS Tools Nexto - Profibus DP and Crevis I/O (KI00349B)
- Program example BCS Tools and iX: Nexto communication with BFI by EtherCAT
- Kom i gang med Nexto XPress - Høyhastighets datalogging (Norwegian)
- BCS Tools/Nexto - Modbus TCP and Crevis I/O, init ST-3702
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus RTU.
- Kom i gang med Nexto XPress - SQL kommunikasjon (Norwegian)
- Kom i gang med Nexto XPress - MQTT kommunikasjon (Norwegian)
- Kom i gang med Nexto XPress - HTML5 websider (Norwegian)
- Kom i gang med Nexto XPress - Grunnleggende (Norwegian)
- Get Started with Nexto Xpress - MQTT communication
- Get Started with Nexto Xpress - The Basics
- Get Started with Nexto Xpress - High speed datalogging
- BCS Tools, MODBUS Symbol Server/Client
- Get started with Nexto Xpress - IEC60870-5-104
- Get started with Nexto Xpress - WebVisu (HTML5)
- Get Started with Nexto Xpress - Database communication
Adverts
Data sheets
Configuration files
Software
Drawings
Knowledge
- BCS Tools Nexto - Task priority and scheduling
- BCS Tools Nexto -After compilation Memory 0 - 6 are presented, what do these mean?
- BCS Tools Nexto - When will the Persistent and Retain variables be saved?
- BCS Tools Nexto - Diagnostic variables with IP address information
- Clarification about the force function in CODESYS
- BCS Tools Nexto - Task information and I/O update synchronization
- BCS Tools Nexto - Download Boot Application during RUN
- BCS Tools - Using the library NextoPID and Util at the same time causes a naming conflict for the PID instruction
- BCS Tools Nexto - Add PID Loops online
- BCS NX3010/3020/3030 - Support of Flood attacks on local and external Ethernet ports
- BCS NX3010/3020/3030 - Real Time Clock (backup time)
- BCS Nexto - CPUs Product Features summary
- BCS Nexto modular/Nexto Xpress - Firmware update procedure
- Codesys - Which systems supports reading milliseconds from RTC
- CODESYS/BCS Tools - Support of REAL (32-bit) and LREAL (64-bit)
- BCS Nexto - How to update firmware in a Nexto CPU in RUN mode
- Nexto serial pinout for COM ports
- Nexto - What is the default IP address?
- Nexto - Reserved ports
- BCS-NX6000 - Single end or differential inputs?
- LTB Life Cycle Notification BCS-NX940x spareparts
- BCS-NX6000 - OpenLoop alarm
- BCS NX6010 - Is it possible to connect mV signal from load cell transmitters
- BCS Tools Nexto - Program example Modbus RTU over TCP - TCP/IP --- JetPort 5601 ---RS485--- NA-9173
- BCS Tools Nexto - Difference between Modbus TCP and Modbus RTU over TCP
- BCS-NX5000 - Gratuitous ARP messages
- BCS NEXTO - Extending network modules
- Profibus DP: Kabelspecifikation PB456/X
- Profibus DP: Aktivt termineringsmotstånd för Profibus
- Profibus DP: Kan en gsd-fil användas till olika Profibus DP I/O?
- Profibus DP: Kabelspecifikation PROFIBUS-DP TPE
- BCS Tools - Backup of GSD data
- BCS-Nexto/Nexto Xpress - Number of supported ARTI connections
- BCS Tools - The address %QBxxxxx not defined in any device
- BCS Tools - OPC connection to the CPU or the simulator in BCS Tools.
- BCS Nexto - ARTI/OPC communication
- Example of a Modbus/TCP client via PLC code using the Oscat library
- BCS Nexto Xpress/Modular - MQTT version
- Nexto I/O update with EtherCat master
- Nexto - Persistent variables loose their value if the name of the application changes
- Nexto - Check operating status of I/O modules
- BCS Tools - Edit CSV files with Excel 2013 or newer might destroy and make the csv files unusable for BCS Tools
Manuals
- BCS-NX3004/NX3005 - Installation guide
- BCS-NX3003/5101 - Installation Guide
- BCS Nexto modular - CPU User's Manual
- BCS-NX4000 - Installation Guide
- BCS NX3010/3020/3030 - Installation Guide
- BCS-NX4010 - Installation Guide
- BCS-NX8000 - User's manual
- BCS-NX8000 - Installation Guide
- BCS-NJ6101 - User's manual
- BCS-NX91xx - User's manual
- BCS-NX90xx - User's manual
- BCS-NJ1001 - User's manual
- BCS-NX1001 - User's manual
- BCS-NX1001 - Installation Guide
- BCS-NX1005 - User's manual
- BCS-NJ1005 - User's manual
- BCS-NX1005 - Installation Guide
- BCS-NJ2001 - User's manual
- BCS-NX2020 - User's manual
- BCS-NX2001 - User's manual
- BCS NX2001 - Installation Guide
- BCS-NX2020 - Installation Guide
- BCS-NJ6000 - User's manual
- BCS-NX6000 - User's manual
- BCS-NX6000 - Installation Guide
- BCS-NX6100 - Installation Guide
- BCS-NX6100 - User's manual
- BCS-NJ6100 - User's Manual
- BCS-NX6020 - User's manual
- BCS-NX6020 - Installation Guide
- BCS-NX6010 - User's manual
- BCS-NX6010 - Installation Guide
- BCS-NJ6020 - User's manual
- BCS-NJ6010 - User's manual
- BCS-NX510x - User's manual
- BCS-NX5000 - User's manual
- BCS-NX5000 - Installation Guide
- BCS-NX5x10 - User's manual
- BCS-NX5001 - User Manual
- BCS-NX5001 - Installation Guide
- BCS Nexto modular/Nexto Xpress - PID advanced library
- BCS Tools - User Manual
- BCS Tools - Programming Manual
- BCS-NX4010 - User's manual
- BCS Tools - Datasheets and specifications
- BCS NX940x - User's manual
- BCS NX92xx - User's manual
- BCS-NX4000 - User's manual
- BCS Nexto Series - Users Manual
- BCS Nexto Series - Technical Characteristics
Firmware
Catalogues
Certificates
- BCS Nexto modular - DNV approval
- BCS Nexto/Nexto Xpress - UL/cUL certificate
- BCS Nexto Modular - CE EMC/LVD Declaration
Information document
Limited availability
BCS-NX6000
Analog input module
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-