BCS-XP325
Compact CODESYS-based controller
- 16 DI (4 fast), 16 DO (4 fast), 5 AI, 2 RTD, 4 AO
- High speed counter input/PTO and PWM outputs
- Ethernet TCP/IP, Serial, USB and CAN interface
- CANopen Master interface
- 3G/4G/WiFi/ETH port (external accessory via USB port)
- SQL integration
- DNV certified
Facts
General
Part number | 66.016.122-1 |
Warranty | 2 year |
Digital inputs (DI) | 16 |
Digital outputs (DO) | 16 |
Voltage and current analog inputs (AI) | 5 |
Voltage and current analog outputs (AO) | 4 |
RTD analog inputs (AI) | 2 |
Ethernet TCP/IP interface | 1 |
RS-485 serial interface | 1 |
CAN interface | 1 |
CANOpen Master protocol | Yes |
J1939 Manager protocol | Yes |
USB host port | 1 |
Addressable input variables memory (%I) | 2 KB |
Addressable output variables memory (%Q) | 2 KB |
Addressable variables memory (%M) | 1 KB |
Symbolic variables memory | 2 MB |
Program memory | 2 MB |
Retain/persistent memory (user configurable) | 7.5KB |
Source code memory (backup) | 26 MB |
User files memory (backup) | 8 MB |
Maximum number of tasks | 5 |
Programming languages | Instruction List (IL), Structured Text (ST), Ladder Diagram (LD), Sequential Function Chart (SFC), Function Block Diagram (FBD), Continuous Function Chart (CFC) |
Online changes | Yes |
Watchdog | Yes |
Real-time clock (RTC) | Yes |
Real-time clock (RTC) resolution | Resolution of 1 ms, max. variance of 3 seconds per day, retention time of 14 days |
Status and diagnostic indication | LEDs, web pages and CPU’s internal memory |
Isolation, Protective earth to all | 1,500 Vac / 1 minute |
Isolation, Logic/RS-485/CAN/USB to all | 1,500 Vac / 1 minute |
Isolation, Ethernet to all | 1,500 Vac / 1 minute |
Isolation, Power supply/analog I/O to all | 1,500 Vac / 1 minute |
Isolation, Digital inputs to all | 1,500 Vac / 1 minute |
Isolation, Digital inputs group I0x to I1x | 1,000 Vac / 1 minute |
Isolation, Digital outputs to all | 1,500 Vac / 1 minute |
Maximum power dissipation | 5 W |
Maximum wire size | 0.5 mm² (20 AWG) with ferrule, 1.5 mm² (16 AWG) without ferrule |
IP level | IP 20 |
Conformal coating | Yes |
Operating temperature | -20 to 60 °C |
Storage temperature | -25 to 75°C |
Operating and storage relative humidity | 5 to 96 %, non-condensing |
Standards | IEC 61131-2, CE, Electromagnetic Compatibility (EMC) and Low-Voltage Directive (LVD) |
Module dimensions (W x H x D) | 215.5 x 98.8 x 34.0 mm |
Package dimensions (W x H x D) | 270.0 x 102.0 x 40.0 mm |
Weight | 370 g |
Weight with package | 430 g |
Certifications
General | CE, UL, UL 61010-2-201, cUL |
Marine | DNV |
Power supply
Nominal input voltage | 24 Vdc |
Input voltage | 19.2 to 30 Vdc |
Maximum input current (in-rush) | 50A / 300 us |
Maximum input current | 300mA |
Digital inputs
Input type | Optoisolated sink type 1. Two isolated groups of 8 inputs each |
Input voltage | 24 Vdc, 15 to 30 Vdc for logic level 1, 0 to 5 Vdc for logic level 0 |
Input impedance | 4.95 kΩ |
Maximum input current | 6.2 mA @ 30 Vdc |
Input state indication | Yes |
Response time | 0.1 ms |
Input filter | 2 ms to 255 ms – by software. The filter sampling is performed on MainTask (or Refresh function), then it's recommended to use multiple values of the task interval |
Transistor digital outputs
Output type | Optoisolated transistor source type |
Maximum output current | 1.5 A per output. 12 A total |
Leakage current | 35 µA |
On state resistance | 105 mΩ |
External power supply | 19.2 to 30 Vdc |
Switching time | 20 us - off-to-on transition @ 24 Vdc. 500 us - on-to-off transition @ 24 Vdc |
Maximum switching frequency | 250 Hz |
Configurable parameters | Yes |
Output state indication | Yes |
Output protections | Yes, protection against surge voltages |
Analog inputs
Input type | Voltage or current input, single ended, individually configured |
Data format | 16 bits in two’s complement, justified to the left |
Converter resolution | 12 bits monotonicity guaranteed, no missing codes |
Conversion time | 400 us (all V/I and RTD channels enabled) |
Input state indication | Yes |
Module protections | Yes, protection against surge voltages and polarity inversion |
Voltage input mode
Range | 0 to 10 Vdc |
Engineering scale | 0 to 30,000 |
Resolution | 2.5 mV |
Precision | ± 0.3 % of full scale rating @ 25 °C. ± 0.010 % of full scale rating / °C |
Over scale | ± 3 % of full scale rating |
Maximum input voltage | 12 Vdc |
Input impedance | 21 kΩ |
Configurable parameters | Signal type per input. Filters |
Low pass filter time constant | 100 ms, 1 s, 10 s or disabled |
Current input mode
Range | 0 to 20 mA, 4 to 20 mA |
Engineering scale | 0 to 30,000 |
Resolution | 5.12 µA |
Precision | ± 0.3 % of full scale rating @ 25 °C. ± 0.015 % of full scale rating / °C |
Over scale | ± 3 % of full scale rating |
Maximum input current | 30 mA |
Input impedance | 119 Ω |
Configurable parameters | Signal type per input. Filters |
Low pass filter time constant | 100 ms, 1 s, 10 s or disabled |
RTD input
Precision | ± 0.5 % of full scale rating @ 25 °C |
Supported scales | PT100, PT1000, 0 to 400 Ω, 0 to 4,000 Ω |
Excitation current | 1 mA |
Resistance range | 0-4,000 Ω |
Configurable parameters | Signal type per input. Filters |
Low pass filter time constant | 100 ms, 1 s, 10 s or disabled |
Maximum sensor cable impedance | 20 Ω |
Analog outputs
Output type | Voltage or current output, individually configured |
Data format | 16 bits in two’s complement, justified to the left |
Converter resolution | 12 bits monotonicity guaranteed, no missing codes |
Update time | 450 us (all outputs enabled) |
Yes | |
Yes, protection against surge voltages and polarity inversion |
Voltage output mode
Range | 0 to 10 V |
Engineering scale | 0 to 30,000 |
Resolution | 2.5 mV |
Precision | ± 0.3 % of full scale rating @ 25 °C. ± 0.025 % of full scale rating / °C |
Stabilization time | 4 ms |
Maximum output value | + 10.3 V |
Load impedance | > 1 kΩ |
Configurable parameters | Signal type per output |
Current output mode
Range | 0 to 20 mA, 4 to 20 mA |
Engineering scale | 0 to 30,000 |
Resolution | 5.18 µA |
Precision | ± 0.3 % of full scale rating @ 25 °C. ± 0.020 % of full scale rating / °C |
Stabilization time | 4 ms |
Maximum output value | + 20.6 mA |
Load impedance | < 600 Ω |
Configurable parameters | Signal type per output |
RS-485
Connector | 3-pin terminal block |
Physical interface | RS-485 |
Communication direction | RS-485: half duplex |
RS-485 maximum transceivers | 64 |
Termination | Yes (Configurable) |
Baud rate | 9600, 19200, 38400, 57600, 115200 bps |
Protocols | Master/Slave MODBUS RTU, Open protocol |
CAN
Connector | 3-pin terminal block |
Physical interface | CAN bus |
32 | |
Termination | Yes (Configurable) |
USB
Connector | USB A Female |
Physical interface | USB V2.0 |
Baud rate | 1.5 Mbps (Low Speed), 12 Mbps (Full Speed) and 480 Mbps (High Speed) |
Ethernet
Connector | Shielded female RJ45 |
Auto crossover | Yes |
Maximum cable length | 100 m |
Cable type | UTP or ScTP, category 5 |
Baud rate | 10/100 Mbps |
Physical layer | 10/100 BASE-TX |
Data link layer | LLC |
Network layer | IP |
Transport layer | TCP (Transmission Control Protocol). UDP (User Datagram Protocol) |
Application layer | EtherCat Master, Ethernet/IP Scanner/Adapter, PROFINET Controller, ModbusTCP client/server, Modbus RTU master/slave, User defined protocol, OPC UA/DA server, MQTT client, CANOpen Master protocol, CAN low level, J1939 Manager protocol, HTTP Server, BCS Tools programming protocol, SNTP Client, SNMP Agent |
Diagnostics | LED (Link/Activity) |
Resources
Manuals
Program examples/Start-up
Drawings
File name | Date | |
---|---|---|
Cable CAB155: Cable for CANopen between any product and BFI | 2022-10-05 15:03:45 | |
Cable CAB114: Cable for ModBus RS485 between Nexto Xpress and BFI | 2022-10-03 10:42:54 | |
BCS Nexto Xpress - CAD symbols | 2022-10-03 10:23:46 |
Knowledge
Certificates
File name | Date | |
---|---|---|
BCS Nexto/Nexto Xpress - UL/cUL certificate | 2022-10-03 10:39:08 | |
BCS Nexto Xpress - UKCA Declaration | 2023-07-06 11:22:57 | |
BCS Nexto Xpress - CE EMC/LVD Declaration | 2023-07-06 11:21:04 | |
BCS Nexto Xpress - DNV approval | 2022-10-03 10:41:44 |
Information document
File name | Date | |
---|---|---|
BCS Tools/BCS Nexto/BCS Nexto Xpress - Revision history | 2024-06-10 11:22:52 |
Configuration files
File name | Date | |
---|---|---|
Configuration file Profinet (xml) for BFI-H3 and BFI-P2 | 2024-08-01 14:55:34 | |
BCS Nexto Xpress - CANopen configuration files | 2022-10-03 10:24:12 |
Firmware
File name | Date | |
---|---|---|
BCS Nexto Xpress - CPU Firmware 1.9.29.0 (transition version) | 2022-09-30 11:10:33 | |
BCS Nexto Xpress - CPU Firmware 1.14.20.0 (current version) | 2024-02-16 17:55:24 |
Brochures
File name | Date | |
---|---|---|
Brochure Nexto Xpress | 2022-09-26 08:41:58 |
Data sheets
File name | Date | |
---|---|---|
BCS Nexto Xpress - Technical datasheet | 2024-01-30 09:53:58 |
Smart Engineering Resources
Limited availability
BCS-XP325
Compact CODESYS-based controller
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: