BFI-E3-14-0041-3F12

Article number 61561

  • Output power 1.5 kW
  • Output 3x400 VAC, 4.1 A
  • Input voltage 3x380-480 VAC
  • IP20

Facts

General description

Article number 61561
Warranty 2 year

Mechanical

IP class IP20
Physical size Size 1
Measurements (H x W x D) 173 mm x 83 mm x 123 mm
Weight 1.0 kg
Typical power loss at rated power 0,02
Main switch No
Built in Main switch, control switch and potentiometer No
Conformal coated PCBs Yes, 3C2/3S2 conformal coated PCBs

Output ratings

Output voltage 3 x 400 VAC
Rated motor current 4.1 A
Overload capacity 150% for 60 seconds, 175% for 2,5 seconds
Motor power 1.5 kW
Output frequency 0 – 500Hz, 0.1Hz resolution
Built-in brake transistor No
Regenerative capacity No brake transistor

Input ratings

Supply voltage 380 – 480VAC ± 10%
Voltage fluctuations +/- 10%
Phase imbalance 3% maximum allowed
Displacement factor > 0.98
Supply frequency 48 – 62Hz
Power cycles 120 per hour maximum, evenly spaced

Control specification

Control modes V/F Voltage Vector, Energy Optimised V/F, Sensorless Vector Speed Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Open Loop PM Vector Control
Current/torque limitation Current limitation
PWM frquency 4-32 kHz effective
Stopping mode Ramp to Stop: User Adjustable 0.1 – 600 seconds,Coast to Stop
Braking Motor Flux Braking
Skip frequency No
Analog setpoint control 0 to 10V, 10 to 0V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
Digital setpoint control 4 fixed speeds, Motorised Potentiometer, Keypad, Modbus RTU, CANopen

Communication

Modbus RTU 9.6 - 115.2 kbps (8N1, 8N2, 8E1, 8O1)
BACnet MS/TP No
Modbus TCP No
Ethernet IP No
EtherCat No
Profinet IO No
Profibus DP(DPV1) No
Device Net No
CC-Link No
CAN open Yes, 125 - 1000 kbps

Display

Programmable display No
Multi language OLED display No
External OLED display Yes
LED display Yes

HVAC

PID-control PI-control with sleep/wake up
Spin start Yes
Pump dry protection No
Pump prime and burst protection No
Stir function No
Motor pre-heat No
Broken impeller and broken belt detection No
Automatic cleaning for pumps No
Bypass control No
Fire mode Yes

Control terminals

Power supply 100 mA @ 24 VDC, 10 mA @ 10 VDC
Inputs 4 in total, 2 Digital, 2 Analog or Digital, selectable
Digital inputs 8-30 V DC, PNP, Response time: < 4 msec, Internal or external supply
Analog inputs Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling
Outputs 2 total, 1 relay, 1 analog or digital
Digital transistor outputs 24VDC/20 mA, Internal supply
Relay outputs Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC
Analog outputs 0 to 10 V, 10 to 0 V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
Safety inputs No
Extra IOs No

Control features

Speed control Master/slave Slave
Modbus master functionality No
Advanced hoist control No
Built-in PLC No

Standard compliances

Low voltage directive 2014/35/EU
EMC directive 2014/30/EU Cat C1 according to EN61800-3:2004
Conformance CE, UL
Machine directive 2006/42/EC
Marine approvals No
Safe torque OFF No
Restriction of hazardous substances RoHS2
Registration evaluation and authorisation of chemicals Reach
Earth leakage current EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing
DC Bus discharge time EN 61800-5-1:2007
Electrostatic discharge EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009.
Dielectric strength 61800-5-1: 2007
Surge EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006.
Electrical fast transient burst EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004.

Ambient conditions

Temperature operation -20 to 50 °C
Humidity 95% max, non-condensing

Maintenance

Fault memory Last 4 Trips stored with time stamp
Data logging Logging of data prior to trip, Current, Temperature, DC Bus Voltage
Maintenence indicator No
Monitoring Hours Run Meter, kWh/MWh meter

Resources

Knowledge

Drawings

Program examples/Start-up

Configuration files

Software


Limited availability

BFI-E3-14-0041-3F12

Article number 61561


EOL - End Of Life:
-

LTB - Last Time Buy:
-

LTD - Last Time Delivery:
-

LTR - Last Time Repair:
-

Replacement Parts: