X2 extreme 12 HP SC

12'' Rugged HMI with iX runtime/CODESYS

  • 1280 × 800 pixel (16:10) TFT-LCD touch screen
  • High brightness display
  • CODESYS control integrated
  • Ethernet 2x100 Mbit
  • -30°C to +70°C operating temperature
  • DNV GL, KR, LR, ABS, CCS, BV, NK, RS marine approvals
  • UL Class I Div 2, ATEX/IECEx Zone 2,22
Contact Print (PDF)

Facts

General description

Part number 640016405
Life cycle status Active
Warranty 2 year

Certifications

General CE, FCC, KCC, UL 61010-2-201, UL 746C
Hazardous ULC1D2, ATEX (Zone2), ATEX (Zone22), IECEx (Zone2), IECEx (Zone22)
Marine KR, LR, ABS, CCS, BV, NK, DNV GL, RS

Mechanical

Mechanical size 340 x 242 x 69mm
Mounting option Panel Mount
Number of touches 1million finger touch operations
Touch type Resistive
Cut-out size 324 x 226mm
Weight 2.8 kg
Housing material Powder-coated aluminum, Black

Power

Input voltage 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies.
Power consumption (max) 27 W
Input fuse Internal DC fuse

System

Hardware platform X2 extreme
CPU i.MX6Quad, Quad ARMCortex-A9 1.0GHz 1MBL2cache
RAM 2 GB
FLASH 4GB SSD(eMMC), 3.5GB free for application

Display

Size diagonal 12.1" diagonal
Resolution 1280x800 pixels
Backlight LED Backlight
Backlight life time 70000 hours
Backlight brightness 1000 cd/m2
Backlight dimming Marine optimized dimming
Display type TFT-LCD with LED backlight

Softcontrol

Codesys runtime version 3.5
Codesys EtherCAT Yes
Codesys Modbus Ethernet Yes
Codesys Modbus RTU Yes
CANopen Yes
Non volatile variables Yes

Serial communication

Number of serial ports 2 Port 9pin DSUB
Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS422/RS485/CAN
Serial port 3 RS485/CAN

Ethernet communication

Number of Ethernet ports 2
Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Ethernet port 2 1x10/100 Base-T (shielded RJ45)

Communication CAN

Number of CAN ports 2
CAN port 1 1 Mbit
CAN port 2 1 Mbit

Expansion interface

SD card SD and SDHC
USB 2xUSB 2.0 500mA

Environmental

Operating temperature -30°C to +70°C
Storage temperature -40°C to +80°C
Shock 40g, half-sine, 11ms according to IEC60068-2-27
Vibration 4g, according to IEC 60068-2-6, Test Fc
Sealing front IP66, NEMA 4X/ 12 and UL Type 4X/ 12
Sealing back IP20
Humidity 5% – 95% non-condensed
Altitude (max) < 3000m

Resources

Knowledge

File name Date
IX otf and ttf fonts 2022-11-23 08:56:14
iX Developer SP7 - 2.47.473 Release information 2022-10-10 16:34:05
Driver MODICON Modbus Slave: Command XDNCW 2022-11-22 20:19:01
Windows CE versions, X2, iX, E1000 2022-10-07 14:47:15
Creating a custom Welcome Screen \ startup screen on a X2 pro operator panel 2022-11-29 15:21:17
Google Gmail end suport for " less secure apps " ends may 30 2022 2023-01-09 13:41:35
iX - SMTP - Using Gmail servers using App password 2022-12-13 15:15:01
How to download Free software packages from SmartStore 2023-08-08 15:52:30
ARTI - 8bit data types not working 2024-10-10 11:05:50
When are Data deleted from the ix x2 database / backup restore database 2023-01-09 13:42:59
OPC ua settings in Phoenix plxnext engineer 2024-08-23 11:54:55
Image Sticking 2022-11-21 15:55:49
Best Practice Database on SD card or flash memory 2023-01-31 13:52:59
Driver Allen Bradley DF1: Behövs 1747-KE kommunikationsmodul ? 2022-12-06 15:49:02
Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411 2023-03-14 10:43:16
Max number of recipe items / tags 2022-09-15 12:37:24
Convert from Exter/E1000 To X2 Series 2022-09-15 12:32:35
X2 BatteryCheck 2024-05-29 11:24:00
X2 Preemptive maintenance 2023-01-09 13:45:19
X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32 2022-09-22 15:36:01
X2 pro (SC) / X2 marine (SC) / X2 extreme (SC) / BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC), Battery replacement 2024-09-13 13:08:34
Nexto Xpress - Program example CANopen X2 Extreme as slave device 2022-10-03 10:32:10
Viewing angle X2 series 2023-02-27 10:53:39
BCS Tools - SFC errors at compile 2024-02-07 08:21:44
X2 control / X2 extreme SC / X2 marine SC / BoX2 pro SC / BoX2 extreme SC, firmware / systemprogram vs Codesys runtime version 2022-09-22 15:52:30

Program examples/Start-up

File name Date
Copy Debug log to accessible folder 2023-06-14 14:22:36
X2 Date time picker script 2023-01-02 14:06:14
Add Tags to Tagmonitor by script 2022-10-31 15:57:37
IX alarm info request lookup in pdf by page index 2023-01-09 13:42:41
Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3. 2022-10-05 15:13:35
Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3. 2022-10-05 15:02:57
IX X2 Backlight \ screensaver ON Event 2023-01-09 13:43:38
Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. 2024-02-21 11:21:02
iX Templates for E-key and X-Key 2022-10-31 15:58:35
X2 update time from Unix timestamp 2023-04-24 08:20:14
Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 2023-04-19 08:44:17
Ping from IX x2 terminal 2022-10-31 15:58:33
iX Developer - Top10 Alarm list, based on count and/or duration 2022-10-14 10:21:57
Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402 2023-03-14 10:29:13
Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 2023-03-14 10:30:39
Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 2023-03-14 10:30:59
Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 2023-03-14 10:29:35
Program example BCS Tools and iX: EtherCAT communication between Nexto PLC/X2control and BFI-P2 BFI-H3 2024-08-09 16:08:05
Program example iX Developer: Project for PLC-program generated in BCS Tools or Smart Engineering for PLC communicating with BFI by bus. 2024-08-15 14:36:39
Program example BCS Tools and iX: Modbus TCP communication between Nexto/X2control/PIO PLC and BFI-E3 2024-08-09 12:48:01
Program example BCS Tools and iX: Modbus RTU communication between Nexto/X2control/PIO PLC and BFI-P2 BFI-H3 BFI-E3 2024-08-09 16:31:53
X2 control / X2 marine SC / X2 extreme SC / BoX2 pro SC / BoX2 extreme SC with CODESYS (all image versions) - Startup, recommendations and limitations (SUEN00392) 2024-07-02 07:58:02
Program example Px (X2/BoX2 control/Nexto Xpress/Modular - BSD v3.37 2024-06-14 08:51:39

Product information

File name Date
​​MTBF Summary X2 pro, X2 control, X2 motion, X2 marine 2022-09-22 13:50:09
X2 export control and dual use 2023-02-08 14:48:11
X2 Letter of Volatility 2023-04-28 09:39:15
Battery test summary - X2 extreme 2022-10-10 11:10:42
Environmental Impact Report X2 extreme 2022-10-14 10:16:56
MTBF summary X2 extreme 2022-10-14 10:16:51

Certificates

File name Date
DoC ECCN for X2 series HMI 2024-03-18 17:18:35
​SDoC Green Passport 2022-09-22 13:49:43
RoHS and REACH Declaration of Conformity 2023-11-22 11:02:47
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion 2022-09-22 13:52:27
ABS Type Approval Certificate X2 extreme sealed 2022-10-14 10:16:08
ABS Type Approval Certificate X2 extreme 2023-04-28 07:31:46
DNVGL Type Approval Certificate X2 extreme sealed 2022-10-14 10:15:40
DNVGL Type Approval Certificate X2 extreme 2022-10-14 10:15:37
LR Type Approval Certificate X2 extreme 2023-07-05 17:33:35
LR Type Approval Certificate X2 extreme sealed 2023-10-31 17:33:15
Compass safe distance X2 extreme 2022-10-14 10:42:28
X2 extreme (SC) / X2 extreme sealed (SC) / BoX2 extreme (SC), CE manufacturer declaration 2024-09-13 10:29:28
X2 extreme (SC) / BoX2 extreme (SC), CCC ex-zone 2024-07-19 09:36:14
Manufacturer declaration: X2 extreme UKCA Declaration of Conformity 2022-10-14 10:42:33
CCS Type Approval Certificate X2 extreme sealed 2022-10-14 10:15:42
CCS Type Approval Certificate X2 extreme 2022-10-14 10:15:19
BV Type Approval Certificate X2 extreme 2023-11-24 13:23:20
BV Type Approval Certificate X2 extreme sealed 2023-11-24 13:26:59
​CCS Marine Certificate X2 extreme, pro, control, marine 2022-09-22 13:43:48
KR Type Approval Certificate X2 extreme sealed 2022-10-14 10:15:48
KR Type Approval Certificate X2 extreme 2022-10-14 10:15:24
NKK Type Approval Certificate X2 extreme sealed 2022-10-14 10:15:51
NKK Type Approval Certificate X2 extreme 2022-10-14 10:15:16
X2 extreme (SC) / BoX2 extreme (SC) update IECEx ATEX 2021 2022-10-14 10:17:09
DoC battery X2 extreme 2024-09-12 13:44:55
DNV Type Approval Certificate X2 Extreme 2023-09-11 18:03:27
CE Certificate X2 extreme 12 HP SC 2022-10-14 10:36:43
FCC Certificate X2 extreme 12 HP SC 2022-10-14 10:40:07

Information document

File name Date
​Guidelines for TxA and TxB migration to X2. 2022-10-10 08:38:10
MTBF X2 extreme 2022-10-14 10:16:14

Brochures

File name Date
X2 series (German) 2022-09-21 08:11:38
X2 brochure (Spanish)​ 2022-09-21 08:12:32
X2 brochure 2019 (French) 2024-01-15 10:52:15
X2 brochure (English), BREN631 2022-09-21 08:11:56
Limited availability

X2 extreme 12 HP SC

12'' Rugged HMI with iX runtime/CODESYS


EOL - End Of Life:
-

LTB - Last Time Buy:
-

LTD - Last Time Delivery:
-

LTR - Last Time Repair:
-

Replacement Parts: